OWN ENERGY ME

SUN-7.6/8K-SG01LP1-EU

Single Phase Hybrid Inverter  | 7.6-8kW | 2 MPPT | LV Battery Supported

7.6-8kW | Single Phase | 2 MPPT | Hybrid Inverter | LV Battery Supported
Remotely shutdown function
Smart Monitoring Platform

Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.

7.6-8kW | Single Phase | 2 MPPT | Hybrid Inverter | LV Battery Supported
  • Colorful touch LCD, IP65 protection degree

  • 6 time periods for battery charging/discharging

  • Max. charging/discharging current of 190A

  • AC couple to retrofit existing solar system

  • Support storing energy from diesel generator

  • Max. 16 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
Technical Specifications
Model SUN-7.6K-SG01LP1-EU SUN-8K-SG01LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 190 190
Max.Discharging Current(A) 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of battery input 1
PV String Input Data
Max. PV Access Power (W)
15200 16000
Max. PV Input Power (W)
9880 10400
Max. PV Input Voltage (V
500
Start-up Voltage(V) 125
MPPT Voltage Range(V) 150-425
Rated PV Input Voltage (V)
370
Max Input Short-Circuit Current(A) 34+34
Max Operating PV Input Current(A) 26+26
No.of MPP Trackers/No.of String Per MPP Tracker 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power(W) 7600 8000
Max AC Input/Output Apparent Power (VA) 8360 8800
Peak Power (off-grid)(W) 2 times of rated power,10s
Rated AC Input/Output Current(A) 34.5/33 36.4/34.8
Max AC Input/Output Current(A) 38/36.3 40/38.3
Max Continuous AC Passthrough (grid to load)(A) 50
Rated Input/Output Voltage/Range(V) 220/230 0.85Un-1.1Un
Grid Connection Form L+N+PE
Power Factor Adjustment Range
0.8 leading to 0.8 lagging
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode
GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range
-40 to +60, >45Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude 2000m
Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet size(W*H*D)[mm] 420×670×233(Excluding connectors and brackets)
Weight[kg] 30
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of Cooling Intelligent air cooling
Grid Regulation IEC 61727, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2